TII&UNISOKU产品
分光仪器首页 > TII&UNISOKU产品 > Unisoku产品 > Optical产品 > 分光仪器 > 激光闪光光解系统 TSP-1000TSP-1000M
激光闪光光解系统 TSP-1000TSP-1000M
发布日期: 2020-03-22  浏览次数:  
\

image is TSP-1000M-02R System
TSP-1000 is a laser flash photolysis system for the measurement of transient absorbance. There are many uses in the analysis of the elementary processes of photochemical reactions. With a nanosecond pulsed laser as the exciting light source, this system measures transient UV-VIS absorption in a broad range from nanosecond to millisecond.
Data are acquired by the combination of a photomultiplier detector and a digital oscilloscope in the single-wavelength monochromator system, and by the combination of a photodiode array detector and a high-speed AD converter in the multi-channel spectrophotometer system. In both systems, time resolution up is available to 10 nsec.

参数

Exciting Light Source (pulsed YAG laser)

Pulse Width

4 ~ 6 nsec

Energy (TSP-1000)

200 mJ @ 532 nm, 60 mJ @ 355 nm

Energy (TSP-1000M)

25 mJ @ 532 nm, 8 mJ @ 355 nm

Repetition Rate

10 Hz (single pulse available)

Monitoring Light Source

Lamp

150 W Xe arc lamp of high stability

Lamp House

Air-cooling type

Light Intensity Adjustment

Iris function with a space to insert an optical filter

Light Guide for Light Path

Material

Fiber optics made of quartz (transmittable in the range of 200 nm ~ 1000 nm)

Length

1 m

Sample Cell Chamber

Temperature Range

5°C ~ 60°C

Temperature Control

By a bath circulator

Cell

10 mm2 quartz cell (transparent in 4 sides)

Spaces for Optical Filters

At the exciting side and the detection side

Data Processor

OS

Windows 95/98/Me/2000/XP

Control Interface

DIO (PCI), GPIB (PCI)

Software

Averaging, Overlaying, Converting of wavelength axis and time axis, Non-linear least square fitting, Data storing in text format



Single-Wavelength Monochromator System

Optical Alignment

Czerny-Turner grating

Focal Distance

200 mm

Speed

F/3.5

Linear Dispersion

8.5 nm/mm

Slit Width

0.1 mm, 0.2 mm, 0.5 mm

Monochromatic Detector

Detector

Photomultiplier tube

Response

5 nsec or less

High-Voltage Power Supply

0 ~ 1100 V adjustable

Control Circuit

Wavelength scanning circuit

Digital Oscilloscope

High-voltage feedback circuit, Sampling rate: 1.25 GS/sec max, Vertical sensitivity: 1 mV/div ~ 10 V/div, Time axis range: 40 nsec/div ~ 10 sec/div



Multi-Channel Spectrophotometer System
*SOLD IN JAPAN ONLY

Spectrometer MD 308

Optical
Alignment

Czerny-Turner, grating

Gratings

3 different gratings automatically changeable

Focal
Length

300 mm

Speed

F/4

Linear
Dispersion

5.4 nm/mm (when using the 600 g/mm grating)

Slit
Width

10 mm ~ 3 mm continuously changeable

Multi-Channel Detector

Detector

Photodiode array 1024ch with a gated image intensifier

Time
Resolution

5nsec ~ 10μsec

Image
Intensifier Gain

Adjustable

Synchronization
Control

Pulse generator with GPIB interface

Wavelength
Width

100 nm, 200 nm, 400 nm (400 nm when using MD 200)



Optional Accessories
 ● Exciting light source 266 nm
 ● Dye laser (420 nm ~ 650 nm)
 ● OPO wavelength-changeable laser
 ● Flash lamp as a monitoring light source
 ● Low-temperature cell chamber (-80°C ~ +100°C)
 ● Stopped-flow mixer (for flow flash measurement)
 ● Bath Circulator
 ● Optical filters


点击观看pdf资料   \


版权所有:贝克斯帝尔科技(北京)有限公司 京ICP备20000437号-1
北京市朝阳区工人体育场北路4号院39号楼418A室
电话:8610-65010355    E-mail:sales@specs-tii.com.cn